# Supersonic® MACH® Key Features

> Explore our advanced features that enhance your diagnostic capabilities and improve user experience.

Source: https://www.supersonicimagine.com/product/features/

### Unparalleled Image Quality

The innovative transducer design and powerful capabilities of software-based architecture are optimizing signal-to-noise ratio at each step of signal processing, offering you an incredible definition in both fundamental and harmonic imaging modes.(2, 3, 4)

A set of advanced features is available to simplify and speed up the image acquisition process.

These include:

- Optimized penetration settings: for visualizing structures at variable depths and in dense breast
- SuperCompound™: fast compounding designed for smooth images with reduced speckle
- SuperRes™: delineation of structures to help improve lesion conspicuity
- TissueTuner™: clear images obtained by matching the speed of sound to tissue density
- AutoTGC™: designed for optimization of the gain for the entire image

### Real-Time ShearWave® PL.U.S.™ & 3D ShearWave®

#### Real-Time ShearWave® Elastography

- ShearWave Elastography Pioneers, first to introduce ShearWave® in real time in 2008
- Superior dynamic non-invasive tissue stiffness evaluation
- ShearWave® comes standard on all transducers*
- Largest ROI on the market
- Available in 2D and 3D imaging
- No lag time, no compromise to b-mode image quality
- 1000+ peer-reviewed publications

**Disabled on the P5-1X transducer*

#### Real-Time 3D ShearWave® Elastography

- Aids in the diagnostic workup of breast lesions and positively impacts patient management (5)
- Contributes to more accurate tumor size estimation and clear margin definition in the preoperative setting (6)
- Plays a role in monitoring and evaluation of breast cancer patients during and after neoadjuvant chemotherapy (7)
- 5. Chen YL, Chang C, Zeng W, et al. 3 Dimensional shear wave elastography of breast lesions: Added value of color patterns with emphasis on crater sign of coronal plane. Medicine (Baltimore). 2016;95(39):e4877. doi: 10.1097/MD.0000000000004877 | Shearwave elastography improves the specificity of breast US: the BE1 multinational study of 939 masses. Berg WA et al. Radiology. 2012 Feb;262(2):4 35 49.
- 6. Accuracy of tumor size measurement: Comparison of B-mode ultrasound, strain elastography, and 2D and 3D shear wave elastography with histopathological lesion size. Farrokh A, Maass N, Treu L, et al. Acta Radiol. 2018;60(4):451-458. doi: 10.1177/0284185118787354. | Shear-wave elastography contributes to accurate tumour size estimation when assessing small breast cancers. Mullen R et al. Clin Radiol. 2014 Dec;69(12):1259-63.
- 7. Feasibility of Imaging and Treatment Monitoring of Breast Lesions with Three-Dimensional Shear Wave Elastography. Athanasiou A, Latorre-Ossa H, Criton A, Tardivon A, Gennisson JL, Tanter M. Ultraschall Med. 2015 Mar 5. | Comparison of strain and shear-wave ultrasonic elastography in predicting the pathological response to neoadjuvant chemotherapy in breast cancers. Ma Y et al. Eur Radiol. 2017 Jun;27(6):2282-2291. | Shear-Wave Elastography for the Detection of Residual Breast Cancer After Neoadjuvant Chemotherapy. Lee SH et al. Ann Surg Oncol. 2015 Dec;22 Suppl 3:S376-84.

### Angio PL.U.S.™

#### Planewave Ultrasensitive® Color Mode Imaging

- Enhanced visualization and clarity in microvasculature and low velocity flow states.
- Significantly improved color sensitivity and spatial resolution while maintaining exceptional 2D imaging.
- Leverages the combination of UltraFast® imaging and 3D wall filtering to create a leap in Doppler imaging performance.
- Ability to detect microvascularization in different types of lesions which opens the door to added clinical information and diagnostic perspectives.

### TRIVU™

#### Three answers in one.

Improve diagnostic confidence and enhance workflow efficiency with unparalleled insights into anatomy, stiffness, and blood flow in a glance.

This cutting edge, real time, **simultaneous** imaging mode displays:

- B-mode
- ShearWave® Elastography
- Angio PL.U.S.™

### UltraFast® Doppler

#### Uniting Doppler Technologies

SuperSonic® MACH®’s UltraFast® imaging has been leveraged to re-invent traditional modes of imaging by uniting ColorFlow Doppler with Pulsed Wave Doppler into a new mode called UltraFast® Doppler, expanding performance and capabilities.

- Up to 300 frames per second in color Doppler to visualized transient phenomena missed by conventional techniques
- Improved workflow with the ability to acquire multiple PW samples on the same acquisition
- Superior post-processing capabilities
- No limitation of color box size
- Improved diagnostic confidence

### Needle PL.U.S.™

Needle Enhancement Imaging and Path Prediction

- Enhanced Visualization: Better real-time visibility of biopsy needles without compromising B-mode image quality.
- Trajectory Prediction: Unmatched precision in predicting needle paths, even with conventional needles.
- Increased Confidence: Boosts procedural confidence for clinicians.

### Liver Assessment Tools

#### Liver Disease Assessment Suite

- Quantitative tools for evaluating chronic liver disease in a non – invasive manner
- ShearWave® PL.U.S.™ Display and quantification in real-time of liver fibrosis
- Att PL.U.S.™ Quantification of beam attenuation, to stage steatosis
- Ssp PL.U.S.™ Measurement of tissue sound speed related to fat content
- Vi PL.U.S.™ Visualization and quantification of tissue viscosity. Displays ShearWave® dispersion, potential for liver inflammation
- Full exam captured within 60 seconds.

## Enhanced real-time ultrasound biomarkers and image clarity for superior clinical value

- Enabling new ultrasound biomarkers
- Next generation image quality
- Crisper, more detailed ultrasound images
- Informed diagnostic decision support
- Precise quantification of ultrasound data
- Enhanced procedural guidance and accuracy

### SonicPad™

#### **A new interface you've already mastered.**

#### Minimize actions and movements for increased workflow and ergonomics with over 25 programmable gestures.

- Our modern, embedded touchpad uses a familiar interface like the kind you already use on your smartphone, tablet or laptop.
- Focus more on what you see and less on wrist fatigue or cleaning a trackball.

### Click

The touch pad click function allows users to enables rapid access to key functions with a single touch.

### Box move

Box move feature allows users to easily reposition and resize diagnostic boxes.

### Sample Volume Size

The touch SV size feature allows users to adjust the sample volume size.

### Clip Navigation

The clip navigation feature enables quick and easy navigation during multiple functions.

### Zoom in

The stretch gesture allows users to magnify specific areas of an image.

### Zoom out

The pinch gesture allows users to reduce the magnification of an image.

### Ergonomics

#### System Features

- Streamlined console
- Customizable buttons and knobs
- SonicPad™
- Low-level noise output
- Lightweight transducers
- 15" Full HD adjustable touchscreen
- 23" Widescreen Full HD Monitor
- Three-position central break
- Large back handle for maneuvering
- Pinless Connector Ports
- Integrated gel warmer with auto-management of heat

### Exam Optimization

#### Reduce Clicks

Users estimate 44% fewer clicks per ultrasound exam when using the SuperSonic® MACH® Ultrasound System’s Automated Protocols feature.

#### Reduce Time

On average the SuperSonic® MACH® Ultrasound System’s Automated Protocols feature reduced the time to perform an abdominal exam from 25 minutes to 11 minutes.

- **100%** of users strongly agree or agree that the SuperSonic® MACH® Ultrasound System’s Automated Protocol feature increases exam efficiency and image acquisition efficiency.
- **100%** of users strongly agree or agree that the SuperSonic® MACH® Ultrasound System’s Automated Protocols will prevent them from missing an image or step in the workflow, therefore providing radiologists more confidence.

*SuperSonic Imagine® Data on File. SuperSonic® MACH 40 Ultrasound System CLT Claims Study. MISC-08417 Rev 001, 2022.*

### Query & Retrieve

**Retrieving prior imaging can be very helpful when used for reference or comparison to the same area of interest in an ultrasound image.**

- Query the PACS server for previous exam(s)
- Side-by-side on-cart display
- Any retrieved exam can be displayed along with a live image in a current exam
- Supported modalities: Ultrasound, Mammography, CT, MRI, Xray, Angiography, Nuclear Medicine and PET
- Fly-through large 3D data sets acquired as series of 2D slices
- Automated query and retrieve linked to MWL and use filters for specific data types
- User may also push studies from PACS workstation to your SuperSonic® MACH® system

### Reporting

#### Dedicated measurements and reporting tools

- Fully customizable report
- Dedicated worksheets for Liver, Breast, Vascular, OB-GYN
- Selection of publications with cut off value per etiology
- BI-RADS®
- TI-RADS

- **97%** of users strongly agree or agree that SuperSonic® MACH® Ultrasound System’s report feature and worksheet includes all information needed to replace handwritten and computer-generated worksheets
- **97%** of users strongly agree or agree that SuperSonic® MACH® Ultrasound System’s report allows for a greater ability to customize images, measurements, patient history, and results in the final report.
- **91%** of users strongly agree or agree that it has never been easier to de-identify and anonymize a patient’s exam than when using the SuperSonic® MACH® Ultrasound System’s “Hide Patient” feature.

*SSI Data on File. SuperSonic® MACH® 40 Ultrasound System CLT CLaims Study. MISC-08417 Rev 001, 2022.*